Physically valid surgical simulators: linear versus nonlinear tissue models.

Sarthak Misra1, K T Ramesh, Allison M Okamura

  • 1Department of Mechanical Engineering, The Johns Hopkins University, MD, USA.

Studies in Health Technology and Informatics
|April 9, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Soft, Degradable, and Magnetic Microcarriers for Encapsulation and Guided Transport of Drugs and 3D Spheroids.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Electronics-free soft robotic minitablet for on-demand gastric molecular sensing and diagnostics in vivo.

Science advances·2026
Same author

Smartphone-based App to Assess Diabetic Peripheral Neuropathy.

Journal of diabetes science and technology·2026
Same author

Physics-informed data-driven discovery of constitutive models with application to strain-rate-sensitive soft materials.

Computational mechanics·2026
Same author

Extremophile survives the transient pressures associated with impact-induced ejection from Mars.

PNAS nexus·2026
Same author

Smartphone-based App to Assess Diabetic Peripheral Neuropathy.

medRxiv : the preprint server for health sciences·2026
Same journal

The Essential Components and Critical Conditions for Success in a Learning Health System in Oncology.

Studies in health technology and informatics·2026
Same journal

Use of Artificial Intelligence in Screening for Adolescent Idiopathic Scoliosis: A Scoping Review.

Studies in health technology and informatics·2026
Same journal

Movement Related Biomechanics in Adolescent Idiopathic Scoliosis: A Review of Reviews.

Studies in health technology and informatics·2026
Same journal

The Impact of Surgical Correction of Adolescent Idiopathic Scoliosis Using Posterior Spinal Fusion on Selected Radiological Parameters and Respiratory Function.

Studies in health technology and informatics·2026
Same journal

Acute Effect of Physio-logic® Exercises on Muscle Tone and Stiffness in Adolescent Idiopathic Scoliosis Patients: A Preliminary Study.

Studies in health technology and informatics·2026
Same journal

Effects of Integrated Music and Occupational Therapy on Motor and Autonomic Function in Children with Neurogenic Scoliosis.

Studies in health technology and informatics·2026
See all related articles

Realistic surgical simulators require accurate tissue interaction models. Nonlinear models capture the Poynting effect, crucial for simulating myocardial tissue forces beyond human perception, enhancing simulator realism and clinical relevance.

Area of Science:

  • Biomedical Engineering
  • Surgical Simulation
  • Computational Mechanics

Background:

  • High-fidelity surgical simulators require realistic modeling of organ-instrument interactions.
  • Existing linear elastic models do not account for nonlinear tissue behaviors like the Poynting effect.

Purpose of the Study:

  • To investigate the significance of the Poynting effect in nonlinear tissue models for surgical simulation.
  • To propose methods for validating surgical simulators based on their impact on clinical outcomes.

Main Methods:

  • Developed a nonlinear model to simulate tissue-organ interactions, incorporating the Poynting effect.
  • Compared force magnitudes predicted by the nonlinear model with psychophysical data on human force discrimination thresholds for myocardial tissue.

Related Experiment Videos

Main Results:

  • The nonlinear model demonstrated that the Poynting effect generates normal forces during tissue shearing.
  • Predicted force differences for myocardial tissue exceeded the just-noticeable difference in human contact force perception.
  • Highlighted the discrepancy between linear and nonlinear models in simulating tissue mechanics.

Conclusions:

  • Nonlinear modeling, specifically accounting for the Poynting effect, is essential for achieving high-fidelity surgical simulation.
  • Simulator validation should focus on parameters influencing clinical outcomes, informed by realistic biomechanical modeling.
  • Accurate force feedback in simulators is critical for training surgeons to perceive subtle tissue interactions.