Related Experiment Video
Updated: Jul 5, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Pediatric multidetector computed tomography using tube current modulation and a patient image gallery
D Honnef1, A H Mahnken, G Haras
1Department of Diagnostic Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, D-52074 Aachen, Germany. honnef@rad.rwth-aachen.de
Background:
Dose reduction is crucial in pediatric multidetector computed tomography (MDCT).
Purpose:
To perform pediatric 16-slice MDCT using tube current modulations and to adjust prospectively the tube current using a patient image gallery (IG) providing simulated dose-reduced protocols; and to evaluate and compare the image quality of the IG and the clinical MDCT.
Material And Methods:
30 examinations (thorax, n = 15; abdomen, n = 8; pelvis, n = 7) in 20 patients (nine male, age 8.05 +/- 7.33 years, weight 29.8 +/- 24.02 kg) were performed according to an IG on a 16-slice MDCT with additional use of online tube current modulation (CARE Dose). Three radiologists visually assessed image quality from the IG and actual 16-slice MDCT scans. For objective analysis, image noise was determined.
Results:
Statistical analysis showed moderate concordance in objective (K = 0.68-0.78) and subjective (K = 0.33-0.64) image assessment between the IG and clinical 16-slice MDCT scans. Depending on the weight group and clinical question, no or only minor dose reductions in the chest, but moderate to considerable reductions in the abdominal/pelvic 16-slice MDCT scans compared to previously used pediatric protocols were achieved. Extra dose reduction was achieved due to additional use of CARE Dose depending on age group and scan region (mean 8.6-23.9%).
Conclusion:
The IG enabled us to prospectively reduce the tube current and adapt the required image quality to the clinical question. Additional dose reduction was achieved with application of CARE Dose; nevertheless, the images are comparable to the simulated images of the IG.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...