The availability and content of dental instrument manufacturers' decontamination information
E M Roebuck1, R Strang, I Green
1Edinburgh Postgraduate Dental Institute, Lauriston Buildings, Lauriston Place, Edinburgh, EH3 9HA. liz.roebuck@nhslothian.scot.nhs.uk
Objective:
The effective decontamination of reusable dental instruments is essential to reduce the risks from onward transmission of infectious diseases. There are therefore a number of legislative requirements placed upon manufacturers of medical devices (which includes dental instruments) to provide validated methods for the reprocessing of such devices. The aim of this study was to determine the availability and content of manufacturer's instructions for the reprocessing of reusable dental instruments.
Materials And Methods:
A database of reusable dental instruments with details of their manufacturers was collated from information received from three dental hospitals. A questionnaire was sent to all the manufacturers requesting information about the reprocessing instructions for their products. The response from each manufacturer was assessed for the quality of the information and compliance with the British, European and International Standard, BS EN ISO 17664 (2004).
Results:
The database from the three dental hospitals included over 800 items supplied by 54 different manufacturers/suppliers. Forty protocols were available for assessing compliance with BS EN ISO 17664 (2004). These protocols accounted for 25 (46%) manufacturers covering 300 devices. The majority (90%) of the returned questionnaires did not comply with the required standard and provided insufficient information to allow for the effective decontamination of the instruments.
Conclusions:
Manufacturers of medical devices are legally required to supply the user with validated instructions to enable effective decontamination of these devices. The information must be in a format as specified in BS EN ISO 17664 (2004). The information obtained in this survey demonstrated that the manufacturers' instructions fall short of the required regulatory requirements. The absence of such instructions increases the risk of cross-infection arising from inadequate cleaning, decontamination and sterilisation.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Good Manufacturing Practices
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated.
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail paint...
Hand hygiene
Hand washing...