Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise
Olaf Dietrich1, José G Raya, Scott B Reeder
1Josef Lissner Laboratory for Biomedical Imaging, Department of Clinical Radiology-Grosshadern, Ludwig Maximilian University of Munich, 81377 Munich, Germany. od@dtrx.net
Abstract:
The statistical properties of background noise such as its standard deviation and mean value are frequently used to estimate the original noise level of the acquired data. This requires the knowledge of the statistical intensity distribution of the background signal, that is, the probability density of the occurrence of a certain signal intensity. The influence of many new MRI techniques and, in particular, of various parallel-imaging methods on the noise statistics has neither been rigorously investigated nor experimentally demonstrated yet. In this study, the statistical distribution of background noise was analyzed for MR acquisitions with a single-channel and a 32-channel coil, with sum-of-squares (SoS) and spatial-matched-filter (SMF) data combination, with and without parallel imaging using k-space and image-domain algorithms, with real-part and conventional magnitude reconstruction and with several reconstruction filters. Depending on the imaging technique, the background noise could be described by a Rayleigh distribution, a noncentral chi-distribution or the positive half of a Gaussian distribution. In particular, the noise characteristics of SoS-reconstructed multichannel acquisitions (with k-space-based parallel imaging or without parallel imaging) differ substantially from those with image-domain parallel imaging or SMF combination. These effects must be taken into account if mean values or standard deviations of background noise are employed for data analysis such as determination of local noise levels. Assuming a Rayleigh distribution as in conventional MR images or a noncentral chi-distribution for all multichannel acquisitions is invalid in general and may lead to erroneous estimates of the signal-to-noise ratio or the contrast-to-noise ratio.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...