Effect of organic mobile phase composition on signal responses for selected polyalkene additive compounds by liquid

Randall E Duderstadt1, Steven M Fischer

  • 1LyondellBasell Industries, 11530 Northlake Dr., Cincinnati, OH 45249, USA. Randall.Duderstadt@lyondellbasell.com

Related Concept Videos

Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and solvents...
Mass Spectrometry: Long-Chain Alkane Fragmentation01:18

Mass Spectrometry: Long-Chain Alkane Fragmentation

The molecular ions of linear alkanes prefer to fragment at the carbon-carbon bond away from the end of the chain since the cleavage of an inner bond creates a stable carbocation and a stable radical. Consequently, the mass signals of linear alkanes feature intense peaks in the middle of the mass-to-charge ratio plot with weaker peaks on either end. The fragmentation of each carbon-carbon bond with the release of a methyl group in each splitting leads to prominent peaks in the mass spectra...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Mass Spectrometry: Alkyne Fragmentation00:53

Mass Spectrometry: Alkyne Fragmentation

The fragmentation of alkynes preferentially occurs at the carbon–carbon bond between the α and β carbon of the alkyne bond to generate a 3-propynyl cation (or propargyl cation). In terminal alkynes, there is the only type of fragmentation that yields the 3-propynyl cation. The unsubstituted 3-propynyl cation exhibits a peak at a mass-to-charge ratio of 39. In internal alkynes, the 3-propynyl cation is substituted. For example, 2-pentyne fragments into methyl-substituted 3-propynyl cation, which...
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...