Related Experiment Video
Updated: Jul 5, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Comparision between bed side testing of blood glucose by glucometer vs centralized testing in a tertiary care
Ayaz Baig1, Imran Siddiqui, Abdul Jabbar
1Section of Chemical Pathology, Department of Pathology & Microbiology, Aga Khan University Karachi, Pakistan. ayaz.baig@aku.edu
Background:
To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital.
Methods:
The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Department of Medicine, Aga Khan University and Hospital Karachi, from April 2005 to March 2006. One hundred and ten patients were included in the study. The blood glucose levels were analyzed on glucometer (Precision Abbott) by finger stick, using Biosensor Technology. At the same time venous blood was obtained to analyze glucose in clinical laboratory on automated analyzer (SYNCHRON CX7) by glucose oxidase method.
Results:
We observed good correlation between bed side glucometer and laboratory automated analyzer for glucose values between 3.3 mmol/L (60 mg/dl) and 16.7 (300 mg/dl). A significant difference was observed for glucose values less than 3.3 mmol/L (p = 0.002) and glucose values more than 16.67 mmol/l (p = 0.049). Mean Turnaround time for glucometer and automated analyzer were 0.08 hours and 2.49 hours respectively. The cost of glucose testing with glucometer was 48.8% lower than centralized lab based testing.
Conclusion:
Bedside glucometer testing, though less expensive does not have good accuracy in acutely ill patient with either very high or very low blood glucose levels.
Related Concept Videos
Hyperglycemia
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Type II Diabetes Mellitus III: Clinical Manifestations and Diagnosis
Hypoglycemia and Glucagon
Diabetes: Symptoms, Diagnosis, and Complications
Automated Microbial Diagnostics