Correction for non-perpendicularity of beam and tilt axis in tomographic reconstructions with the IMOD package
1Boulder Laboratory for Three-dimensional Electron Microscopy of Cells, Department of Molecular, Cellular, and Developmental Biology, University of Colorado, Boulder, CO 80309, USA. mast@colorado.edu
Abstract:
A correction for non-perpendicularity between the beam axis and the tilt axis in electron tomographic tilt series has been implemented in the IMOD software package and its value and limitations have been explored. Correction for this effect can provide a significant improvement in the alignment error and the reconstruction quality in some cases. However, when the projection model being fit includes an anisotropic shrinkage (i.e. stretch) in the plane of the specimen, adding a variable for the beam tilt does not produce a lower alignment error; it is thus not possible to distinguish between the effects of stretch and beam tilt. Test reconstructions indicate that an alignment solution that includes stretch will adequately correct for the effects of a beam tilt. For specimens subject to deformation under the beam, an alignment solution that accounts for stretch is preferable to one that accounts for beam tilt instead, provided that the markers used for alignment are sufficiently well distributed. Otherwise, a correction for beam tilt should be used.
Related Concept Videos
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal centroidal axes. The...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Shear on the Horizontal Face of a Beam Element