Beyond the reaction progress variable: the meaning and significance of isotopic incorporation data

Carlos Martínez Del Rio1, Richard Anderson-Sprecher

  • 1Department of Zoology and Physiology, University of Wyoming, Laramie, WY, 82072-3166, USA. cmdelrio@uwyo.edu

Oecologia
|May 1, 2008
PubMed

Related Concept Videos

Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
¹H NMR Signal Integration: Overview00:58

¹H NMR Signal Integration: Overview

The intensity of a signal, which can be represented by the area under the peak, depends on the number of protons contributing to that signal. The area under each peak is shown as a vertical line called an integral, with the integral value listed under it, as seen in the proton NMR spectrum of benzyl acetate. Each integral value is divided by the smallest integral value to obtain the ratio of the number of protons producing each signal. The ratio reveals the relative number of protons and not...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Isotopes and Radioisotopes01:28

Isotopes and Radioisotopes

In the early 1900s, English chemist Frederick Soddy realized that an element could have atoms with different masses that were chemically indistinguishable. These different types are called isotopes — atoms of the same element that differ in mass. Isotopes differ in mass because they have different numbers of neutrons but are chemically identical because they have the same number of protons. Soddy was awarded the Nobel Prize in Chemistry in 1921 for this discovery.
An isotope containing more...
Isotopes01:12

Isotopes

Elements have a set number of protons that determines their atomic number (Z). For example, all atoms with eight protons are oxygen; however, the number of neutrons can vary for atoms of the same element. The sum of the number of protons and the number of neutrons is the mass number (A). Atoms with the same atomic number but different mass numbers are called isotopes. Elements can have multiple isotopes, for example, carbon-12, carbon-13, and carbon-14.An element's atomic mass, or weight, is a...