Related Experiment Video
Updated: Jul 5, 2026

An Efficient and Rapid HPLC-QQQ-MS Method for the Quantitation of Tropane Alkaloids in Medicinal Plants
Published on: June 12, 2026
Counterfeit homeopathic medicinal products: syrups. A simple and rapid LC-ESI-MS method to detect preservatives not
Alessia Panusa1, Luigi Gagliardi
1Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy. alessia.panusa@unimi.it
Abstract:
A rapid and simple LC-ESI-MS method for the simultaneous detection and quantitation of six preservatives in homeopathic syrups has been developed. Counterfeit homeopathic syrups are suspected to contain preservatives that are not declared in label. For this reason a method to ascertain the absence of sorbic and benzoic acids, methyl-, ethyl-, propyl- and butyl-parabens, as the most frequently utilised preservatives, has been developed. Analytes were eluted with a linear gradient of acetonitrile-5mM ammonium acetate in 12 min using 2,4-dichlorobenzylalchol as Internal Standard. The HPLC separation was performed on an Eclipse XDB-C18 (2.1 mm x 50 mm-5 microm) column and the ESI-MS detection was performed in negative ion mode. Linearity of the method was studied in the range of 2 pg to 10 ng injected and correlation coefficients r2 > or =0.9992 were obtained. LOD ranged from 0.04 to 0.4 ng mL(-1).