Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Blood volume monitoring
Roland E Winkler1, Wolfgang Pätow, Peter Ahrenholz
1PDA Rostock, Department of Internal Medicine, Nephrology and Dialysis, Rostock, Germany.
Background:
In CKD stage 5 diabetic patients (DM), only approximately half of the interdialytic weight gain was accounted for by sodium intake. The other half was due to pure water gain, probably caused by hyperglycemia. Dialysis treatment faces two major troubles: the removal of the extra amount of water and the therapy of the compromised compensatory mechanisms. The described situation is the reason why new technologies in hemodialysis were developed. Blood volume monitoring (BVM) with regulation of ultrafiltration and sodium (Hemocontrol, Hospal, Belgium; Hameomaster, Nikkiso Co. Ltd, Japan) was evaluated to describe the advantages for efficacy and compatibility in hemodialysis therapy.
Methods:
18 cardiovascular instable patients (DM) were included into the study (age 56.4 +/- 12.5, 7 female, 11 male). Begin of dialysis 39 +/- 9.3 months before the study, dialysis time/session 258.3 +/- 15.4 min, 3 sessions/week, blood flow 250 ml/min, dialysate flow 500 ml/min, prephase: standard bicarbonate dialysis (HD; HCO3 - 35 mmol/l) 2 weeks, BVM: 48 weeks. Clinical parameters evaluated before BVM and 48 weeks after BVM: number of muscle cramps (MC) and hypotensive episodes (HypoEp) during dialysis, optimal weight (OptW), single pool Kt/V (sp Kt/V), equilibrated Kt/V (db Kt/V), systolic blood pressure (BP), antihypertensive drugs (AntiDr), cardiac ejection fraction (EF) and left ventricular mass index (LVMI).
Results:
In comparison with HD after 48 weeks with BVM, we can demonstrate a reduction of MC by 83.7%, HypoEp by 88.9%, OptW by 1.7%. The improved refilling and reduction of OptW led to an increase of sp Kt/V by 34.8% and db Kt/V by 33.3%. AntiDr were reduced to 56.6% compared to HD, BP lowered by 4.4%. Due to BVM, EF increases to 123.8% and LVMI decreases by 25.2%.
Conclusion:
BVM can improve clinical parameters for adequacy of hemodialysis. It offers a unique possibility to treat diabetic patients according to their special needs.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...