Related Experiment Video
Updated: Jul 5, 2026

07:48
Eye Tracking During A Complex Aviation Task For Insights Into Information Processing
Published on: April 4, 2025
Testing the reliability of an eye-dedicated triaging system: the RESCUE
T Rossi1, B Boccassini, C Cedrone
1Ospedale Oftalmico, ASL RM E, Unita Operativa Complessa di Chirurgia Vitreoretinica, Roma - Italy. tommaso.rossi@usa.net
European Journal of Ophthalmology
|May 10, 2008
Summary
The Rome Eye Scoring System for Urgency and Emergency (RESCUE) accurately triages urgent eye conditions. This validated system demonstrates high sensitivity and specificity in prioritizing emergency ophthalmology patients.
Area of Science:
- Ophthalmology
- Emergency Medicine
- Healthcare Systems
Background:
- Establishing urgency in ophthalmology can be challenging.
- Efficient patient prioritization is crucial in emergency eye care.
Purpose of the Study:
- To evaluate the reliability and accuracy of the Rome Eye Scoring System for Urgency and Emergency (RESCUE).
- To determine RESCUE's effectiveness in identifying urgent ophthalmic cases.
Main Methods:
- A 1000-patient cohort was triaged using RESCUE based on pain, redness, vision loss, and globe injury risk.
- RESCUE scores were correlated with retrospective urgency assessments (diagnosis, treatment, hospitalization).
- Key performance metrics including accuracy, sensitivity, and specificity were calculated.
Main Results:
- RESCUE demonstrated high accuracy (95%), sensitivity (90.7%), and specificity (97.2%).
- The system showed a significant correlation between RESCUE scores and actual urgency (p<0.001).
- False positive rate was 9.3%, and false negative rate was 2.7%.
Conclusions:
- RESCUE is a reliable eye-dedicated triage system for prioritizing urgent ophthalmic cases.
- The system's performance confirms its ability to effectively identify patients requiring immediate attention.
- Implementing RESCUE can improve the management of emergency eye conditions.