Related Experiment Video
Updated: Jul 5, 2026

Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Thromboembolic prophylaxis with intermittent pneumatic compression devices in trauma patients: a false sense of
Chona Macatangay1, S Rob Todd, Alan H Tyroch
1Thomason Hospital Trauma Department, El Paso, TX, USA.
Purpose:
Intermittent pneumatic compression devices provide a safe and attractive means of venous thromboembolism prophylaxis. We hypothesized that intermittent pneumatic compression devices were inadequate prophylaxis secondary to noncompliance.
Methods:
This was a prospective double-blind study evaluating compliance with intermittent pneumatic compression devices in nonambulatory adult trauma patients. Compliance was evaluated for the first 3 days of admission. The study consisted of two 3-month stages (before and after hospital personnel education on the importance of venous thromboembolism prophylaxis).
Findings:
During the first stage, device compliance was 85%, 59%, and 74% in the intensive care unit, surgical ward, and overall, respectively. Following hospital personnel education, device compliance was 82%, 65%, and 77% in the intensive care unit, surgical ward, and overall, respectively. There was no significant difference in compliance between the 2 stages.
Conclusions:
With inadequate compliance and the cost attributed with intermittent pneumatic compression devices, other means of venous thromboembolism prophylaxis should be considered first, specifically low-molecular-weight heparin if not contraindicated.