Related Experiment Video
Updated: Jul 5, 2026

Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
Modification of the submerged coil to prevent microbial carryover error in thermal death studies
Susanne E Keller1, Arlette G Shazer, Gregory J Fleischman
1U.S. Food and Drug Administration, National Center for Food Safety and Technology, 6502 South Archer Road, Summit-Argo, Illinois 60501, USA. susanne.keller@fda.hhs.gov
Abstract:
A submerged coil unit generates death rate data for foodborne pathogens through precise computer-controlled sequential sampling rather than the usual manually timed, labor-intensive single sampling associated with other approaches. Our work with Yersinia pseudotuberculosis and Listeria monocytogenes Scott A using the submerged coil unit indicated non-log-linear death rates with large degrees of tailing. Varying degrees of cell adhesion to the surface of the exit port resulted in carryover that was likely the primary cause of these non-log-linear kinetics. This carryover also resulted in erroneously high measured levels of thermal resistance for both organisms. To address the carryover problem, modifications were made to the exit port of the submerged coil unit to ensure continuous and uniform heat treatment. These modifications resulted in a 2-fold decrease in measured D-values for L. monocytogenes Scott A and a 10-fold decrease in measured D-values for Y. pseudotuberculosis. D-values measured with the modified machine for L. monocytogenes Scott A were similar to those found in the literature. Slight tailing in survival curves persisted with the modified method, particularly for Y. pseudotuberculosis. These results indicate that kinetic data for microbial death rates obtained using an unmodified submerged coil unit must be viewed with suspicion in light of the significant potential for carryover.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
