Published on: May 2, 2017
Glucose and insulin variations in patients during the time course of a FDG-PET study and implications for the
Mohiuddin Hadi1, Stephen L Bacharach, Millie Whatley
1Department of Radiology, University of California, San Francisco, CA 94158, USA. dochadi@gmail.com
Introduction:
2-Deoxy-2[(18)F]fluoro-d-glucose (FDG) positron emission tomography (PET) has an established role in the evaluation of cancer. Generally, tumor uptake and response to treatment are evaluated using the standardized uptake value (SUV). Some authors have proposed correcting SUV for glucose levels. Insulin is also thought to influence tumor uptake by changing uptake in other tissues. However, little attention has been paid to understanding the variability of glucose or insulin during a single PET study.
Method:
We studied the biological and instrumental variability of glucose and insulin measurements in 71 nondiabetic patients undergoing FDG-PET studies. Multiple glucose measurements were obtained in all 71 subjects, and in 69 of these 71 subjects, multiple serum insulin measurements were made. We determined the coefficient of observed variation (CV(ow)) and the coefficient of variation attributable to biological variability (CV(bv)) for both glucose and insulin.
Results:
The mean glucose concentration was 78.9+/-13.5 mg/dl. The mean insulin value was 6.49+/-5.92 microU/ml. The weighted mean CV(ow) and CV(bv) was 5.0% and 3.6%, respectively, for glucose and 14.2% and 8.3%, respectively, for insulin.
Conclusions:
Variations in the range of 3.6% are observed in glucose measurements during the time course of an FDG scan even after accounting for analytical error; larger variations of 8.3% are observed in insulin levels. Therefore, corrections of SUV for blood glucose, especially if obtained from single measurements, can introduce additional errors of at least this much.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)