Related Experiment Video
Updated: Jul 5, 2026

A Standardized Pipeline for Examining Human Cerebellar Grey Matter Morphometry using Structural Magnetic Resonance Imaging
Published on: February 4, 2022
Evaluation and comparison of GLM- and CVA-based fMRI processing pipelines with Java-based fMRI processing pipeline
Jing Zhang1, Lichen Liang, Jon R Anderson
1Health Informatics Graduate Program, University of Minnesota, Minneapolis, MN 55455, USA. jzhang0000@gmail.com
Abstract:
Activation patterns identified by fMRI processing pipelines or fMRI software packages are usually determined by the preprocessing options, parameters, and statistical models used. Previous studies that evaluated options of GLM (general linear model)--based fMRI processing pipelines are mainly based on simulated data with receiver operating characteristics (ROC) analysis, but evaluation of such fMRI processing pipelines on real fMRI data is rare. To understand the effect of processing options on performance of GLM-based fMRI processing pipelines with real fMRI data, we investigated the impact of commonly-used fMRI preprocessing steps; optimized the associated GLM-based single-subject processing pipelines; and quantitatively compared univariate GLM (in FSL.FEAT and NPAIRS.GLM) and multivariate CVA (canonical variates analysis) (in NPAIRS.CVA)-based analytic models in single-subject analysis with a recently developed fMRI processing pipeline evaluation system based on prediction accuracy (classification accuracy) and reproducibility performance metrics. For block-design data, we found that with GLM analysis (1) slice timing correction and global intensity normalization have little consistent impact on fMRI processing pipelines, spatial smoothing and high-pass filtering or temporal detrending significantly increases pipeline performance and thus are essential for robust fMRI statistical analysis; (2) combined optimization of spatial smoothing and temporal detrending improves pipeline performance; and (3) in general, the prediction performance of multivariate CVA is higher than that of the univariate GLM, while univariate GLM is more reproducible than multivariate CVA. Because of the different bias-variance trade-offs of univariate and multivariate models, it may be necessary to consider a consensus approach to obtain more accurate activation patterns in fMRI data.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).

