Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD
Christof Karmonik1, Richard Klucznik, Goetz Benndorf
1Department of Radiology, The Methodist Hospital Research Institute, Houston, TX, USA. ckarmonik@tmhs.org
Objective:
Computational Fluid Dynamic (CFD) is increasingly being used for modeling hemodynamics in intracranial aneurysms. While CFD techniques are well established, need for validation of the results remains. By quantifying features in velocity patterns measured with 2D phase contrast magnetic resonance (pcMRI) in vivo and simulated with CFD, the role of pcMRI for providing reference data for the CFD simulation is explored.
Methods:
Unsteady CFD simulations were performed with inflow boundary conditions obtained from 2D pcMRI measurements of an aneurysm of the anterior communication artery. Intra-aneurysmal velocity profiles were recorded with 2D pcMRI and calculated with CFD. Relative areas of positive and negative velocity were calculated in these profiles for maximum and minimum inflow.
Results:
Areas of positive and of negative velocity similar in shape were found in the velocity profiles obtained with both methods. Relative difference in size of the relative areas for the whole cardiac cycle ranged from 1%-25% (average 12%).
Conclusion:
2D pcMRI is able to record velocity profiles in an aneurysm of the anterior commuting artery in vivo. These velocity profiles can serve as reference data for validation of CFD simulations. Further studies are needed to explore the role of pcMRI in the context of CFD simulations.
Related Concept Videos
Aneurysm I: Introduction
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Average Velocity
Instantaneous Velocity - II
Escape Velocity
To calculate the escape velocity, it is assumed that no energy is lost to any frictional forces. In practice, a satellite...