Related Experiment Video
Updated: Mar 24, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography
Charalampos Tsoumpas1, Federico E Turkheimer, Kris Thielemans
1Hammersmith Imanet, part of GE Healthcare, London, United Kingdom. charalampos.tsoumpas@imperial.ac.uk
Abstract:
In dynamic positron emission tomography (PET) studies, the time changing activity of the radiotracer is measured through multiple consecutive frames. Subsequent pixel-by-pixel application of the appropriate kinetic model provides quantitative information in terms of images of the distribution of the physiological parameter of interest. In this context, iterative reconstruction methods may be used to reconstruct for each time frame a static image of appreciable higher quality than the analytical algorithms, especially in low-count cases. Furthermore, if the reconstruction algorithm also models the kinetics of the measured counts, the parametric image is expected to be of even higher quality. In this work, we investigate the methodology to directly reconstruct parametric images in three-dimensional PET when the kinetic model is linear in its parameters (Patlak plot) and compare with indirectly estimated parametric maps, where the radioactivity distribution was estimated by the filtered back projection and ordered subsets expectation maximization algorithms. Both real and simulated data for tracers with irreversible kinetics in brain studies are included. The results demonstrate appreciable smaller standard deviation and mean squared error characteristics for the direct reconstruction. However, some regions may converge slowly. The FBP and ordered subsets expectation maximization (OSEM) indirect estimations have a similar level of bias after matching their resolutions, but OSEM has smaller standard deviation.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
14:21Creating Dynamic Images of Short-lived Dopamine Fluctuations with lp-ntPET: Dopamine Movies of Cigarette Smoking
Published on: August 6, 2013
Related Concept Videos
Pharmacodynamic Models: Direct Effect Model and Indirect Response Model
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Mechanistic Models: Compartment Models in Individual and Population Analysis