Related Experiment Video
Updated: Jul 5, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Risk factors for dissatisfaction with the indoor environment in open-plan offices: an analysis of COPE field study
G R Newsham1, J A Veitch, K E Charles
1Institute for Research in Construction, National Research Council Canada, Ottawa, ON, Canada. guy.newsham@nrc-cnrc.gc.ca
Unlabelled:
We applied binary logistic regression techniques to data collected from 779 participants in a field study of open-plan ('cubicle') offices conducted in nine buildings. Independent variables were physical conditions in the workplace, and dependent variables were derived from occupant satisfaction measures; personal characteristics were included as covariates. There was a significantly higher risk of dissatisfaction with privacy and acoustics (defined as being below the 20th percentile as opposed to being above the 80th percentile) associated with being in a small workstation, or being seated next to a window. A higher risk of dissatisfaction with ventilation was associated with being seated next to a window, temperatures substantially higher than the average neutral temperature, and a carbon dioxide concentration greater than 650 ppm. A higher risk of dissatisfaction with lighting was associated with panel heights greater than 66 inches (1.7 m), high reflected glare on computer screens, desktop illuminances outside 300-500 lux, desktop illuminance uniformity (min/max ratio) less than 0.5, and being in a workstation distant from a window.
Practical Implications:
We have demonstrated statistically significant relationships between indoor environment conditions in office spaces and environmental dissatisfaction risk. Although generally supported by prior research, not all of these risk factors are reflected in existing recommended practice documents for office design. Consideration of these findings in future revisions of such documents may be warranted.
Related Concept Videos
Self-Discrepancy Theory
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Dimensions of Health and Illness
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Stereotype Content Model