Pitfalls of diagnosis based on abnormal flow cytometry and [(18)F]fluorodeoxyglucose positron emission tomography
Parul Bhargava1, J Anthony Parker, Bruce J Dezube
1Department of Pathology, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA. pbhargav@bidmc.harvard.edu
Abstract:
A 30-year-old, HIV-positive man with a previous history of an atypical nasopharyngeal Burkitt lymphoma developed fluorodeoxyglucose (FDG) avidity on a routine FDG-positron emission tomography (PET)/computed tomography scan performed 10 months after the completion of all treatment. This new FDG-avid disease was in the area of his initial disease. Flow cytometric assessment of a fine needle aspiration showed a CD10-expressing B-cell population with kappa predominance. The corresponding cytology smears had large atypical lymphoid cells along with smaller lymphocytes and macrophages. Because of the patient's previous history of a CD10(+), high-grade B-cell lymphoma, the cytologic and flow cytometric findings were considered highly suspicious for a B-cell lymphoma. Because the differential diagnosis included a relapsed Burkitt lymphoma versus a second, unrelated lymphoma (the former with a dismal prognosis) it was deemed prudent to obtain more tissue via an open biopsy for confirmation of diagnosis and exact subclassification. An open biopsy, however, revealed a reactive lymph node with enlarged geographic follicles; no lymphoma was demonstrable and c-Myc studies were negative. The patient remains without evidence of disease. Retrospectively, the original flow cytometric assessment was believed to likely represent sampling of hyperplastic germinal centers with significantly expanded CD10(+) B cells. The FDG uptake and the kappa predominance further confounded the interpretation. This case illustrates the pitfalls of standard diagnostic techniques, including PET scanning, cytology, and flow cytometry, particularly in the setting of HIV. It further underscores the importance of adequate clinical correlation and a low threshold for performing open biopsies in such patients.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Flow Cytometry
In...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

