Solute descriptors for characterizing retention properties of open-tubular columns of different selectivity in gas
Sanka N Atapattu1, Colin F Poole
1Department of Chemistry, Wayne State University, Detroit, MI 48202, USA.
Abstract:
An iteration procedure is used to optimize the solute descriptors for 94 compounds suitable for characterizing the retention properties of open-tubular columns for gas chromatography in the intermediate temperature range of 160-240 degrees C. These solute descriptors are used to calculate the system constants of the solvation parameter model for nine open-tubular columns (SPB-Octyl, HP-5, Rtx-440, Rxi-50, Rtx-OPP, DB-1701, DB-225, HP-Innowax, and HP-88) at increments of 20 degrees C from 160 to 240 degrees C. The optimized descriptors afford a two- to three-fold improvement in the fit to the retention model compared with literature values as determined by the standard deviation of the difference between the model predicted and experimental retention factors (log k). Combining literature values for the system constants at lower temperatures (60-140 degrees C) with those obtained here allowed system maps to be constructed for the nine columns over the full temperature range of 60-240 degrees C. For a wide temperature range the system maps indicate that the relationship between the system constants and temperature is non-linear and that polar interactions are likely to be important in relative and absolute terms to quite high temperatures.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Analyte Adsorption and Distribution
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology