Abstract:
Coacervates made of surfactant aggregates, namely aqueous and reverse micelles and vesicles, were firstly used as solvents in single-drop microextraction (SDME) and proposed for the extraction and concentration of chlorophenols prior to liquid chromatography. The formation of coacervate drops in the needle tip of conventional microsyringes depended on the type of intermolecular forces established between the surfactant headgroups making up the supramolecular aggregates; hydrogen bond interactions were strong enough to permit the formation of spherical drops. Stability of 1-50 microL coacervate drops was achieved by introducing the microsyringe needle tip in a PTFE rod, the end of which had been machined out with a heated flanging-tool to get circular flanges (diameters in the range 3.5-6 mm). The parameters affecting the efficiency of single-drop coacervative microextraction (SDCME) were investigated using vesicular coacervates as a solvent and 2-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) as model analytes. Coacervative microextraction dynamics fit to the general rate equation of liquid-liquid extraction. The effect of variables such as extraction time, drop volume, stirring rate, pH and temperature, on the extraction of chlorophenols was similar to that described for organic solvent drops. Electrolyte concentrations above 0.1 M caused drop instability. Under the optimum conditions, detection limits were in the range 0.1-0.3 microg L(-1). The relative standard deviation was between 4.3 and 5.6 at 20 microg L(-1) spiked level. The method was applied to the determination of the four chlorophenols in wastewater, superficial water from a reservoir and groundwater and the recoveries were in the range 79 and 106% at 5-20 microg L(-1) spiked level.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
09:48Employing Pressurized Hot Water Extraction (PHWE) to Explore Natural Products Chemistry in the Undergraduate Laboratory
Published on: November 7, 2018
Related Concept Videos
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Instrumentation