Numerical study of the performance improvement of the APSK transmission system using zero-nulling method
Hidenori Taga1, Jyun-Yi Wu, Wei-Tong Shih
1National Sun Yat-Sen University, No.70 Lien-Hai Road, Kaohsiung 80424 Taiwan ROC. hidenoritaga@mail.nsysu.edu.tw
Optics Express
|June 4, 2008
Summary
This study theoretically analyzes amplitude and phase shift keying (APSK) transmission. It evaluates the zero-nulling method
Area of Science:
- Optical Communications
- Digital Signal Processing
Background:
- Amplitude and Phase Shift Keying (APSK) is a modulation format with a trade-off between Amplitude Shift Keying (ASK) and Phase Shift Keying (PSK) performance, influenced by the ASK extinction ratio.
- The zero-nulling method has been proposed to enhance PSK performance, but it can reduce total system capacity.
Purpose of the Study:
- To theoretically investigate the transmission performance of APSK formats.
- To evaluate the effectiveness of the zero-nulling method in improving PSK performance under identical total system capacity.
Main Methods:
- Theoretical analysis of APSK transmission performance.
- Comparative study of modulation techniques considering extinction ratio and zero-nulling impact.
Main Results:
- The study quantifies the effectiveness of the zero-nulling method in enhancing PSK performance.
- Identified the conditions under which the zero-nulling method is beneficial without compromising total system capacity.
Conclusions:
- The zero-nulling method can be effectively employed to improve PSK performance in APSK systems.
- Maintaining identical total system capacity is crucial when implementing the zero-nulling method for optimal results.
Related Concept Videos
Transmission Line Design Considerations
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
Power Factor Correction
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
Maximum Power Flow and Line Loadability
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
Reducing Line Loss
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Multimachine Stability
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Fast Decoupled and DC Powerflow
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations: