A selective chromogenic molecular sensor for acetate anions in a mixed acetonitrile-water medium

Shuzhen Hu1, Yong Guo, Jian Xu

  • 1Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, P. R. China.

Related Concept Videos

Titration in Nonaqueous Solvents01:16

Titration in Nonaqueous Solvents

Most acid-base titrations are performed in an aqueous medium. In aqueous titrations, water competes with weaker acids or bases for proton donation or acceptance, leading to ambiguous endpoints in the titration curve. Water also affects the partial ionization of weak acids or bases. For example, water accepts a proton from acetic acid to form hydronium and acetate ions. The hydronium ion formed is a stronger acid than acetic acid, and the acetate ion is a stronger base than water. As a result,...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Titration of a Weak Acid with a Weak Base01:08

Titration of a Weak Acid with a Weak Base

Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...