Related Experiment Video
Updated: Jul 4, 2026

Robotic Myotomy and Partial Fundoplication for Achalasia
Published on: August 11, 2023
Endoscopic full-thickness plication for the treatment of GERD by application of multiple Plicator implants: a
Daniel von Renteln1, Ingolf Schiefke, Karl-Hermann Fuchs
1Medizinische Klinik I, Klinikum Ludwigsburg, Ludwigsburg, Germany.
Background:
The full-thickness Plicator allows transmural suturing at the gastroesophageal (GE) junction to restructure the antireflux barrier. Studies of the Plicator procedure to date have been limited to placement of a single transmural suture to create the endoscopic gastroplication.
Objective:
The purpose of this study was to evaluate the safety and efficacy of placing multiple transmural sutures for the treatment of GERD.
Design:
Open-label, prospective, multicenter study.
Setting:
Four tertiary-referral centers.
Patients:
Subjects with symptomatic GERD who require daily maintenance proton pump inhibitor (PPI) therapy. Study exclusions were hiatal hernia >3 cm, grades III and IV esophagitis, Barrett's epithelium, and esophageal dysmotility.
Interventions:
Forty-one patients received two or more transmural sutures placed linearly in the anterior gastric cardia approximately 1 cm below the GE junction.
Main Outcome Measurements:
Six months after the procedure, median GERD-health-related quality of life (HRQL) improved 76% compared with off-medication baseline (6.0 vs 25.0, P < .001), with 75% of patients (32/40) achieving >50% improvement in their baseline GERD-HRQL score. Six months after the procedure, daily PPI therapy was eliminated in 70% of patients (28/40). Heartburn symptoms improved 80% compared with off-medication baseline (16.0 vs 84.0, P < .001). Median esophagitis grade improved 75% compared with baseline (0.0 vs 1.0, P = .005). Esophageal pH assessed as median distal esophageal-acid exposure (percentage time pH < 4.0) improved 38% compared with baseline (9.0 vs 11.0, P < .020; nominal P value for a single statistical test: significance removed upon the Bonferroni adjustment for multiple testing of data) and manometric outcomes were also improved compared with baseline (median lower esophageal sphincter resting pressure improved 25% [10.0 vs 6.0, P < .017; nominal P value for a single statistical test: significance removed upon the Bonferroni adjustment for multiple testing of data]) and median amplitude of contraction improved 11% (70.0 vs 62.0, P < .037; nominal P value for a single statistical test: significance removed upon the Bonferroni adjustment for multiple testing of data).
Limitations:
Small sample size. No randomized comparison with a single implant group.
Conclusions:
Endoscopic full-thickness plication with multiple serially placed implants was safe and effective in reducing GERD symptoms, medication use, esophageal-acid exposure, and esophagitis.
Related Concept Videos
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures V: ERCP
Patient...
