Scale-variant magnification for computational integral imaging and its application to 3D object correlator.

Dong-Hak Shin1, Hoon Yoo

  • 1Dept. of Visual Contents, Dongseo University, San69-1, Jurye2-Dong, Sasang-Gu, Busan 617-716, Korea. shindh2@dongseo.ac.kr

Optics Express
|June 12, 2008
PubMed
Summary

This study introduces a new scale-variant magnification technique for volumetric computational reconstruction (VCR) to enhance 3D object correlator resolution. The method overcomes elemental image interference, improving reconstructed image quality.

Related Concept Videos

Introduction to Scalers01:21

Introduction to Scalers

Many familiar physical quantities can be specified completely by giving a single number and the appropriate unit. For example, "a class period lasts 50 min," or "the gas tank in my car holds 65 L," or "the distance between the two posts is 100 m." A physical quantity that can be specified completely in this manner is called a scalar quantity. The word "scalar" is a synonym for "number." Time, mass, distance, length, volume, temperature, and energy are some examples of scalar quantities.
Scalar...
Divergence Theorem in 3D Space01:20

Divergence Theorem in 3D Space

In vector calculus, flux measures the total flow of a vector field through a surface. For a closed surface in three-dimensional space, this means measuring how much of the field passes outward through every point on the boundary. Directly calculating this flux can be difficult when the surface has a complicated or irregular shape. The Divergence Theorem provides a powerful alternative by relating surface flux to behavior inside the enclosed region.The Divergence Theorem states that the outward...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Cylinders in Three-Dimensional Space01:28

Cylinders in Three-Dimensional Space

A cylindrical surface is generated when a two-dimensional profile curve is translated along a straight line in three-dimensional space. The translated copies of the curve form a surface composed of parallel rulings, each oriented in the same fixed direction. This construction allows many three-dimensional forms to be described using relatively simple planar equations.In Cartesian coordinates, a cylindrical surface is often recognized by an equation that omits one of the three variables. For...
Three-Dimensional Analysis of Strain01:29

Three-Dimensional Analysis of Strain

Three-dimensional strain analysis is crucial for understanding how materials deform under stress, particularly in elastic, homogeneous materials. This method employs principal stress axes to simplify complex stress states into more understandable forms. Subjected to stress, a small cubic element within a material either expands or contracts along these axes, transforming into a rectangular parallelepiped. This transformation effectively illustrates the material's deformation. The principal...