Parametrization and application of scatter kernels for modelling scanned proton beam collimator scatter dose
Peter Kimstrand1, Erik Traneus, Anders Ahnesjö
1Section of Oncology, Department of Oncology, Radiology and Clinical Immunology, Uppsala University, Akademiska Sjukhuset, S-751 85 Uppsala, Sweden. Peter.Kimstrand@onkologi.uu.se
Abstract:
Collimators are routinely used in proton radiotherapy to laterally confine the field and improve the penumbra. Collimator scatter contributes up to 15% of the local dose and is therefore important to include in treatment planning dose calculation. We present a method for reconstruction of the collimator scatter phase space based on the parametrization of pre-calculated scatter kernels. Collimator scatter distributions, generated by the Monte Carlo (MC) package GEANT4.8.2, were scored differential in direction and energy. The distributions were then parametrized so as to enable a fast reconstruction by sampling. MC calculated dose distributions in water based on the parametrized phase space were compared to full MC simulations that included the collimator in the simulation geometry, as well as to experimental data. The experiments were performed at the scanned proton beam line at the The Svedberg Laboratory (TSL) in Uppsala, Sweden. Dose calculations using the parametrization of this work and the full MC for isolated typical cases of collimator scatter were compared by means of the gamma index. The result showed that in total 96.7% (99.3%) of the voxels fulfilled the gamma 2.0%/2.0 mm (3.0%/3.0 mm) criterion. The dose distribution for a collimated field was calculated based on the phase space created by the collimator scatter model incorporated into the generation of the phase space of a scanned proton beam. Comparing these dose distributions to full MC simulations, including particle transport in the MLC, yielded that in total for 18 different collimated fields, 99.1% of the voxels satisfied the gamma 1.0%/1.0 mm criterion and no voxel exceeded the gamma 2.6%/2.6 mm criterion. The dose contribution of collimator scatter along the central axis as predicted by the model showed good agreement with experimental data.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022