Related Experiment Video
Updated: Jul 4, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Ion exchange chromatography of proteins-predictions of elution curves and operating conditions. II. Experimental
S Yamamoto1, K Nakanishi, R Matsuno
1Department of Food Science and Technolgy, Faculty of Agriculture, Kyoto University, Sakyo-ku, Kyoto 606, Japan.
Abstract:
The applicability and validity of the model developed in Part I were confirmed experimentally. In this article, various proteins were eluted both by stepwise and linear gradient elution on DEAE ion exchangers under a variety of experimental conditions. Adsorption isotherms were measured as a function of ionic strength in batch experiments. The moment method was employed for the determination of various parameters such as the gel-phase diffusion coefficient and the longitudinal dispersion coefficient. By use of these parameters and the experimentally measured ionic strength of the peak position, the number of plates was determined according to the method described in Part I. Theoretical elution curves were calculated with the experimentally measured adsorption equilibria and the number of plates. Good agreement was observed between theory an experiments. Various factors affecting the separation were investigated. It was found that the effect of the number of plates for salts, N'(p), was negligible except the case of stepwise elution of high ionic strength buffer. When elution curves were symmetrical, the widths of the elution curves were inversely proportional to the square root of the number of plates of proteins, N(p), as in other chromatographic techniques. A simple graphical method for prediction of the peak position in linear gradient elution described in Part I was found applicable when the elution curves were symmetrical. A useful correlation of prediction of the peak width in a linear gradient elution was proposed on the basis of the approximate solution derived in Part I of this study. This graphical method and correlation permit easy prediction of the peak position and peak width in linear gradient elution in the case of symmetrical elution curves.
Related Concept Videos
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...

