Related Experiment Video
Updated: Jul 4, 2026

08:31
Anaerobic Protein Purification and Kinetic Analysis via Oxygen Electrode for Studying DesB Dioxygenase Activity and Inhibition
Published on: October 3, 2018
Measuring oxygen diffusion coefficients with polarographic oxygen electrodes: I. Electrolyte solutions
1Department of Chemical Engineering, State University of New York at Buffalo, Buffalo, New York 14260.
Biotechnology and Bioengineering
|October 1, 1985
Summary
No abstract available in PubMed .
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Potentiometry: Membrane Electrodes
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Measuring Reaction Rates
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Potentiometry: Types of Electrodes
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Special considerations while measuring oxygen saturation
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Controlled-Potential Coulometry: Electrolytic Methods
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
The chosen potential ensures...

