Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Wavelet-based correlations of skin temperature and blood flow oscillations
Sergey Podtaev1, Matvey Morozov, Peter Frick
1Department of Physics, Perm State University, Bukireva str. 15, Perm, Russia. podtaev@termodat.ru
Abstract:
The wavelet transform-based correlation analysis has been used to study skin temperature fluctuations caused by periodic changes in blood flow resulting from oscillations in vasomotor smooth muscle tone. We considered two cases, one in which temperature measurements and blood flow recordings by laser Doppler flowmetry are made simultaneously and another in which two temperature signals are measured concurrently. Twelve healthy subjects participated in our study. The gapped wavelet technique was used to suppress artifacts caused by boundary effects. Simultaneous recordings of skin temperature fluctuations and the signal of the laser Doppler flowmeter provided correlation coefficients essentially exceeding the values obtained for noise signals within three spectral ranges corresponding to myogenic (0.05-0.14 Hz), neurogenic (0.02-0.05 Hz), and endothelial (0.0095-0.02 Hz) regulation mechanisms. Within the frequency range from 0.14 to 2 Hz the values of the correlation function are compatible with the values of noise correlations. The same results were obtained for two concurrently measured temperature signals. Reduction in the amplitude of temperature fluctuations and in the level of correlations with the frequency arises because the skin has the properties of a low-frequency filter. As temperature fluctuations propagate their amplitude decays as an exponential function of frequency. Hence small oscillations in the spectral range reflecting the influence of heartbeat and respiration cannot be distinguished from external thermal noise.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Applications of Integration to Find Blood Flow
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...