Related Experiment Video
Updated: Jul 4, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Effective doses in radiology and diagnostic nuclear medicine: a catalog
Fred A Mettler1, Walter Huda, Terry T Yoshizumi
1Department of Radiology and Nuclear Medicine, New Mexico Veterans Administration Healthcare System, 1501 San Pedro Blvd, Albuquerque, NM 87108, USA. fmettler@salud.unm.edu
Abstract:
Medical uses of radiation have grown very rapidly over the past decade, and, as of 2007, medical uses represent the largest source of exposure to the U.S. population. Most physicians have difficulty assessing the magnitude of exposure or potential risk. Effective dose provides an approximate indicator of potential detriment from ionizing radiation and should be used as one parameter in evaluating the appropriateness of examinations involving ionizing radiation. The purpose of this review is to provide a compilation of effective doses for radiologic and nuclear medicine procedures. Standard radiographic examinations have average effective doses that vary by over a factor of 1000 (0.01-10 mSv). Computed tomographic examinations tend to be in a more narrow range but have relatively high average effective doses (approximately 2-20 mSv), and average effective doses for interventional procedures usually range from 5-70 mSv. Average effective dose for most nuclear medicine procedures varies between 0.3 and 20 mSv. These doses can be compared with the average annual effective dose from background radiation of about 3 mSv.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...