Related Experiment Video
Updated: Jul 4, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and
François De Guio1, Hugues Benoit-Cattin, Armel Davenel
1Cemagref, Food Process Engineering Research Unit, 35 044, Rennes, France. francois.de-guio@cemagref.fr
Objective:
Characterization of magnetic susceptibility artefacts with assessment of the gradient-echo signal decay function of echo time, pixel size, and object geometry in the case of air-filled cylinders embedded in water.
Materials And Methods:
Experiments were performed with a 0.2 T magnet on a network of small interacting air-filled cylinders along with Magnetic resonance imaging (MRI) simulations integrating intravoxel dephasing. Signal decay over echo time was assessed at different pixel sizes on real and simulated images. The effects of radius, distance between cylinders and main magnetic field were studied using simulation.
Results:
Signal loss was greater as echo time or pixel size increased. Voxel signal decay was not exponential but was weighted by sinus cardinalis functions integrating echo time, pixel size and field inhomogeneities which depended on main magnetic field strength and geometric configuration of the object. Simulation was able to model signal decay, even for a complex object constituted of several cylinders. The specific experimental signal modulation we observed was thus reproduced and explained by simulation.
Conclusion:
The quantitative signal decay approach at 0.2 T can be used in characterization studies in the case of locally regular air/water interfaces as the signal depends on object size relative to pixel size and is relevant to the geometric configuration. Moreover, the good concordance between simulation and experiments should lead to further studies of magnetic susceptibility effects with other objects such as networks of spheres. MRI simulation is thus a potential tool for molecular and porous media imaging.
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers energy to a nearby...