Abstract:
Exercise induced hemodynamic stress has been studied extensively using a wide range of physiological sensors. While athletes can modulate their training intensity using EKG-based heart rate monitors, there are currently no noninvasive monitors that can be used to ascertain with a high degree of certainty the hemodynamic stress an individual is experiencing because of fatigue or an underlying pathology. We propose that cardiac stress will result in detectable changes in skin blood flow. In a clinical trial with eleven healthy subjects performing the Bruce Protocol treadmill test low frequency waves were observed in the blood flow to both the forehead and ear, but not the finger, using photople- thysmographs (PPG) measured by a pulse oximeter. As volitional fatigue approached, the low frequency (f = 0.05-0.2 Hz) amplitude modulation observed in the PPG became more pronounced; then, within several seconds of the cessa- tion of the protocol, they disappeared. Using a software-based detector, these distinct waves are reliably detected, with a low incidence of false positives, in all subjects before the onset of volitional fatigue. We hypothesize that the low frequency waves observed in the PPG of individuals exercising to volitional fatigue provide a mechanism for noninvasively detecting hemodynamic stress to the human vascular system.
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...