Simultaneous measurements of oxygen diffusion coefficients and solubilities in fermentation media with polarographic

L K Ju1, C S Ho, R F Baddour

  • 1Department of Chemical Engineering, State University of New York at Buffalo, Buffalo, New York 14260.

Related Concept Videos

Microbial Growth Measurement: Indirect Methods01:27

Microbial Growth Measurement: Indirect Methods

Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...
Special considerations while measuring oxygen saturation01:19

Special considerations while measuring oxygen saturation

Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important. 
Microbial Growth Measurement: Direct Methods01:23

Microbial Growth Measurement: Direct Methods

Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...