Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Evaluation of liquid-phase microextraction conditions for determination of chlorophenols in environmental samples
1Department of Chemistry, National Chung-Hsing University, Taichung 40227, Taiwan, ROC.
Abstract:
Determination of trace chlorophenols (CPs) in environmental samples has been evaluated using liquid-phase microextraction (LPME) coupled with gas chromatography-mass spectrometry (GC-MS) without derivatization. The LPME procedure used to extract CPs from water involved 15 microL 1-octanol as acceptor solution in a 5.0 cm polypropylene hollow fiber with an inner diameter of 600 microm and a pore size of 0.2 microm. Under the optimal extraction conditions, enrichment factors from 117 to 220 are obtained. The obtained linear range is 1-100 ng mL(-1) with r(2)=0.9967 for 2,4-dichlorophenol (2,4-DCP); 1-100 ng mL(-1) with r(2)=0.9905 for 2,4,6-trichlorophenol (2,4,6-TCP); 5-500 ng mL(-1) with r(2)=0.9983 for 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and 10-1000 ng mL(-1) with r(2)=0.9929 for pentachlorophenol (PCP). The limits of detection range from 0.08 to 2 ng mL(-1), which is comparable with the reported values (12-120 ng mL(-1)). Recoveries of CPs in various matrices exceed 85% with relative standard deviations of less than 10%, except for PCP in landfill leachate. The applicability of this method was examined to determine CPs in environmental samples by analyzing landfill leachate, ground water and soil. The 2,4-DCP and 2,4,6-TCP detected in the landfill leachate are 6.68 and 2.47 ng mL(-1). The 2,4,6-TCP detected in ground water is 2.08 ng mL(-1). All the studied CPs are detected in contaminated soil. The proposed method is simple, low-cost, less organic solvent used and can potentially be applied to analyze CPs in complex environmental matrices.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II