Related Experiment Video
Updated: Jul 4, 2026

Method to Measure Tone of Axial and Proximal Muscle
Published on: December 14, 2011
Activation characteristics of trunk muscles during cyclic upper-body perturbations caused by an oscillating pole
Christoph Anders1, Beatrix Wenzel, Hans C Scholle
1Clinic for Trauma-, Hand- and Reconstructive Surgery, Division for Motor Research, Pathophysiology and Biomechanics, University Hospital Jena, Jena, Germany. christoph.anders@med.uni-jena.de
Objective:
To evaluate the effect of a new device on trunk muscle activation.
Design:
Cross-sectional survey of trunk muscle activation characteristics.
Setting:
Physiologic laboratory at university institute.
Participants:
Thirty healthy subjects (15 men, 15 women) were recruited from a university campus.
Interventions:
A simple flexible pole that applies rapidly alternating forces on the trunk when set into motion was used. The device was held horizontally in both hands, in front of the body. It was used at 3 different oscillation frequencies (3, 3.5, 4.5 Hz), in horizontal and vertical plane, respectively.
Main Outcome Measures:
Surface electromyography of 5 trunk muscles was measured and the data were normalized according to relative cycle time. Time dependent (amplitude curve) and time independent (mean amplitude over cycle) parameters were used for analysis.
Results:
Rectus abdominis and external oblique muscle amplitudes were directly proportional with oscillation frequency (analysis of variance), and these effects were independent of sex. Multifidus amplitude levels were subject to oscillation plane with increased levels for vertical oscillation in men but not in the women. All abdominal muscles exhibited continuous activation pattern, independent of oscillation plane. Back muscles changed from a continuous activation in horizontal plane into similarly phasic patterns in vertical oscillation plane. The occurring amplitude peak moved forward in relative cycle with increasing oscillation frequency.
Conclusions:
Back muscle activation patterns were subject to oscillation plane. Abdominal muscle activation was independent from oscillation frequency and oscillation plane. These normative data may be used to identify disturbed trunk muscle coordination patterns and to control success of functional restoration during rehabilitation interventions of back pain patients.
Related Concept Videos
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played by the...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and play a...
Excitation-Contraction Coupling in Skeletal Muscles
When an action potential...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Forced Oscillations