Related Experiment Video
Updated: Jul 4, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
The incidence of early radiolucencies about a pegged glenoid component using cement pressurization
Shane Barwood1, Kevin J Setter, Theodore A Blaine
1Department of Orthopaedic Surgery, Columbia University, New York, NY, USA.
Abstract:
Glenoid component loosening is the most common early mode of failure of total shoulder arthroplasty (TSA) We hypothesised that the use of a pegged glenoid component with a modern glenoid reaming system and an instrumented cement pressurization technique would achieve a low prevalence of early radiolucent lines. Of 81 patients having TSA with a cemented, all polyethylene, 3-peg glenoid component for primary glenohumeral osteoarthritis, 69 had high quality radiographs available for analysis. All preoperative and initial postoperative radiographs were reviewed and graded in a blinded manner using previously established criteria. When the radiolucency grade of cement fixation was converted to a numeric scale of 0 (no radiolucency) to 5 (grossly loose), the mean cementing score was 0.14 + 0.06. Of the 69 shoulders, 62 (90%) had no radiolucencies. These techniques to improve glenoid fixation resulted in a low incidence of early radiolucencies about the glenoid component in patients having TSA for primary glenohumeral osteoarthritis.