A Passive Ankle Dorsiflexion Testing System for an In Vivo Model of Overuse-induced Tendinopathy
Published on: March 1, 2024
Achilles tendon Doppler flow may be associated with mechanical loading among active athletes
Peter Malliaras1, Paula J Richards, Giorgio Garau
1School of Health Science and Social Care, Brunel University, Uxbridge, Middlesex, UK. peter.malliaras@brunel.ac.uk
Background:
Tendon Doppler flow may be associated with tendon pain in symptomatic patients, but the relationship between Doppler flow and pain among athletes who are still competing is unclear.
Hypothesis:
Among active athletes, Doppler flow may partly reflect tendon adaptation to increased mechanical load and/or asymptomatic tendinopathy.
Study Design:
Cross-sectional study; Level of evidence, 3.
Methods:
The Achilles tendons of 61 badminton players (24 elite, 37 recreational) were examined with gray-scale and color Doppler ultrasound. Achilles tendon pain and activity level (badminton training, badminton playing, badminton years) were measured.
Results:
Doppler flow was not associated with current Achilles tendon pain but was associated with an increased anteroposterior tendon diameter (an indicator of tendinopathy) (P = .02). Athletes who had been playing badminton for longer were more likely to have Doppler flow (P < .01), and there was a trend toward an association between a greater number of badminton playing hours per week and Doppler flow (P = .07).
Conclusion:
Achilles tendon Doppler flow appears to be a sign of asymptomatic tendinopathy rather than pain among active athletes. The association between weekly badminton hours and badminton years and Doppler flow suggests that Doppler flow may be a response to mechanical load in this cohort.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection