Related Experiment Video
Updated: Jul 3, 2026

08:51
Quantification of Coenzyme A in Cells and Tissues
Published on: September 27, 2019
Validated comprehensive analytical method for quantification of coenzyme A activated compounds in biological tissues
Christoph Magnes1, Maria Suppan, Thomas R Pieber
1Institute of Medical Technologies and Health Management, Joanneum Research, Auenbruggerplatz 20,8036 Graz, Austria.
Analytical Chemistry
|July 11, 2008
Summary
We developed a new method to measure all coenzyme A (CoA) activated compounds in tissues. This reliable technique accurately quantifies acyl-CoAs, crucial for understanding cellular metabolism.
Area of Science:
- Biochemistry
- Analytical Chemistry
- Metabolomics
Background:
- Coenzyme A (CoA) esters are vital metabolites involved in numerous cellular processes.
- Accurate quantification of acyl-CoAs is essential for understanding metabolic pathways and disease states.
- Existing methods for acyl-CoA analysis can be complex and lack comprehensive coverage.
Purpose of the Study:
- To establish a robust and comprehensive analytical method for identifying and quantifying the entire class of acyl-CoAs.
- To enable accurate measurement of short-, medium-, and long-chain acyl-CoAs in various biological tissues.
- To provide a reliable tool for metabolomic studies involving CoA-activated substances.
Main Methods:
- Development of an online solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS).
- A simplified three-step sample preparation protocol: buffer/solvent/standard addition, homogenization, and centrifugation.
- Direct injection of the supernatant into the SPE-LC/MS/MS system for analysis.
Main Results:
- The method demonstrated excellent accuracy (87–107%) and precision (0.1–12.8%) for acyl-CoA fatty acids in mouse skeletal muscle.
- Achieved a low limit of quantification, below 3.1% of physiological levels in 200 mg of mouse tissue.
- Validated across multiple tissues including mouse liver, adipose tissue, and rat liver, with no observed matrix effects.
Conclusions:
- The developed SPE-LC/MS/MS method is robust, reliable, and comprehensive for acyl-CoA analysis.
- This method facilitates accurate quantification of diverse acyl-CoAs in biological samples.
- It offers a valuable tool for advancing research in metabolic biochemistry and disease diagnostics.