Effect of solution pH and ionic strength on the separation of albumin from immunoglobulins (IgG) by selective

S Saksena1, A L Zydney

  • 1Department of Chemical Engineering, University of Delaware, Newark, Delaware 19716.

Although protein fractionation by selective membrane filtration has numerous potential applications in both the downstream processing of fermentation broths and the purification of plasma proteins, the selectivity for proteins with only moderately different molecular weights has generally been quite poor. We have obtained experimental data for the transport of bovine serum albumin (BSA) and immunoglobulins (IgG) through 100,000 and 300,000 molecular weight cutoff polyethersulfone membranes in a stirred ultrafiltration device at different solution pH and ionic strength. The selectivity was a complex function of the flux due to the simultaneous convective and diffusive solute transport through the membrane and the bulk mass transfer limitations in the stirred cell. Under phsioligical conditions (pH 7.0 and 0.15 M NaCI) the maximum selectivity for the BSA-IgG separation was only about 2.0 due primarily to the effects of protein adsorption. In contrast, BSA-IgG selectivities as high as 50 were obtained with the same membranes when the protein solution was at pH 4.8 and 0.0015 M NaCl. This enhanced selectivity was a direct result of the electrosatatic contributions to both bulk and membrane transport. The membrane selectivity could actually be reversed, with higher passage of the larger IgG molecules, by using a 300,000 molecular weight cutoff membrane at pH 7.4 and an ionic strength of 0.0015 M NaCl. These results clearly demonstrate that the effectiveness of selective protein filtration can be dramatically altered by appropriately controlling electrostatic interactions through changes in pH and/or ionic strength. (c) 1994 John Wiley & Sons, Inc.

Related Concept Videos

Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Two-dimensional Gel Electrophoresis01:22

Two-dimensional Gel Electrophoresis

Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as  cells...
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
Filtration00:53

Filtration

Filtration is a physical separation process that involves passing a suspension through a porous medium to separate solids from fluids. During filtration, solids collect on the porous medium while liquids, also collectively known as the filtrate, pass through. The filtration medium is selected based on the filtration purpose, quantity, and nature of the precipitate. The general criteria for a suitable filtering medium are that it is inert, mechanically strong, nonabsorbent toward dissolved...
Immunoprecipitation01:20

Immunoprecipitation

Immunoprecipitation, or IP, is a widely used technique that employs protein-antibody interactions to isolate proteins or protein complexes in their native state for studying protein-protein interactions, quaternary structures, or supramolecular complexes. Various modifications of the technique, including chromatin IP, cross-linking IP, and fluorescence IP, are commonly used.
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...