Related Experiment Video
Updated: Jul 3, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Mapping of the norepinephrine transporter in the human brain using PET with (S,S)-[18F]FMeNER-D2
Akihiro Takano1, Andrea Varrone, Balázs Gulyás
1Karolinska Institutet, Department of Clinical Neuroscience, Psychiatry Section, Stockholm, Sweden.
Abstract:
We have evaluated the detailed mapping of the norepinephrine transporter (NET) in the human brain with (S,S)-[(18)F]FMeNER-D(2) using a template method and the generation of functional ROIs based on the PET information. Brain PET measurements were performed from 90 to 210 min after the injection of (S,S)-[(18)F]FMeNER-D(2) in 20 healthy male subjects. Binding potential (BP(ND)) was calculated as late time ratio of the target region to the reference region (caudate) minus one. BP(ND) template images were generated from mean parametric images obtained in a group of 10 subjects using SPM2. On the BP(ND)/MRI template images, functional ROIs based on several different BP(ND) thresholds for the thalamus and brainstem were generated automatically using PMOD 2.8 software in addition to anatomical ROIs. PET/MRI data of another group of 10 subjects were used to evaluate the validity of the template method and the functional ROIs. NET BP(ND) template images demonstrated higher binding in the medial thalamus whereas the anterior and the pulvinar divisions had lower binding. In the brainstem, high binding was detected around the cerebral aqueduct of the midbrain and within the dorsal pons, in a volume comprising locus coeruleus. Functional ROIs with higher BP(ND) thresholds naturally yielded higher BP(ND) and lower coefficients of variance than did anatomical ROIs. This study indicated that (S,S)-[(18)F]FMeNER-D(2) combined with a template method provides detailed information on the distribution of NET in vivo and that functional ROIs on the template would be useful in further clinical studies.
More Related Videos
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
15:10A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET