Related Experiment Video
Updated: Jul 3, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Correlation between external exposure and activity in patients undergoing 131I thyroid cancer therapy
R Barquero1, F Basurto, H R Vega-Carrillo
1Hospital Universitario del Río Hortega, E-47010 Valladolid, Spain. rbarquero@hurh.sacyl.es
Abstract:
The uptake and clearance of 131I activity for inpatients undergoing cancer therapy were determined from routine external dose survey measurements. A bi-exponential behavior was found, with the two time constants representing the iodine dynamics in the thyroid on one hand and in the rest of the body on the other. The external dose at 1 m from the patient was correlated to the activity in the thyroid remnant and inside the body, the averaged value being 52.8 +/- 11.4 microSv GBq(-1) h(-1). The temporal evolution of activity in the body, the urinary system and the thyroid remnant area were determined taking into account the clearance from thyroid and whole body (effective retention constants averages 0.23 +/- 0.14 d(-1) and 1.46 +/- 0.34 d(-1)) and the uptake in thyroid (3.15 +/- 3.36%). Applications of this study in the public and environmental radiation protection areas are presented.
Related Concept Videos
Biological Effects of Radiation
Hyperthyroidism I: Introduction
Radiological Investigation I: X-ray and CT
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The iodine is then...
Hyperthyroidism II: Pathophysiology
Graves' Disease I: Introduction