Multimodal imaging approaches: PET/CT and PET/MRI
Bernd J Pichler1, Martin S Judenhofer, Christina Pfannenberg
1Laboratory for Preclinical Imaging and Imaging Technology, University of Tübingen - Department of Radiology, Röntgenweg 13, 72076, Tübingen, Germany. bernd.pichler@med.uni-tuebingen.de
Abstract:
Multimodality imaging, specifically PET/CT, brought a new perspective into the fields of clinical and preclinical imaging. Clinical cases have shown, that the combination of anatomical structures, revealed from CT, and the functional information from PET into one image, with high fusion accuracy, provides an advanced diagnostic tool and research platform. Although PET/CT is already an established clinical tool it still bears some limitations. A major drawback is that CT provides only limited soft tissue contrast and exposes the patient or animal, being studied, to a significant radiation dose. Since PET and CT scanner are hard-wired back to back and share a common patient bed, PET/CT does not allow simultaneous data acquisition. This temporal mismatch causes image artefacts by patient movement between the two scans or by respiration motion. To overcome these limitations, recent research concentrates on the combination of PET and MRI into one single machine. The goal of this development is to integrate the PET detectors into the MRI scanner which would allow simultaneous data acquisition, resulting in combined functional and morphological images with an excellent soft tissue contrast, very good spatial resolution of the anatomy and very accurate temporal and spatial image fusion. Additionally, since MRI provides also functional information such as blood oxygenation level dependant (BOLD) imaging or spectroscopy, PET/MRI could even provide multi-functional information of physiological processes in vivo. First experiments with PET/MRI prototypes showed very promising results, indicating its great potential for clinical and preclinical imaging.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT