Evaluation of linear accelerator performance standards using an outcome oriented approach
Related Experiment Video
Updated: Jul 3, 2026

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
Alejandra Rangel1, Nicolas Ploquin, Ian Kay
1Department of Medical Physics, Tom Baker Cancer Centre, 1331-29 St NW, Calgary T2N 4N2, Canada. alejrang@cancerboard.ab.ca
Abstract:
Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest.
More Related Videos
Related Concept Videos
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care evaluation by...
Nursing Evaluation
Section...
Cancer Survival Analysis
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...
Standards of Care II

