Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 3, 2026

Measuring and Modeling Contractile Drying in Human Stratum Corneum
08:00

Measuring and Modeling Contractile Drying in Human Stratum Corneum

Published on: March 1, 2017

Two new methods for preparing a unique stratum corneum substitute.

Daniël Groen1, Gert S Gooris, Maria Ponec

  • 1Leiden/Amsterdam Center for Drug Research, Department of Drug Delivery Technology, Gorlaeus Laboratories, University of Leiden, P.O. Box 9502, 2300 RA Leiden, The Netherlands.

Biochimica Et Biophysica Acta
|July 26, 2008
PubMed
Summary

New methods enhance the stratum corneum substitute (SCS), a synthetic skin barrier model. The linomat method offers superior lipid uniformity and reduced loss, making it ideal for skin permeation studies.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Fibroblast-derived matrix human skin equivalents reveal distinct roles for papillary and reticular fibroblasts in human skin barrier integrity and aging.

Scientific reports·2026
Same author

Mild psoriasis as a suitable model for proof-of-mechanism in a phase 1B setting: Results from a double-blind placebo-controlled trial with guselkumab.

British journal of clinical pharmacology·2025
Same author

A Versatile, Low-Cost Modular Microfluidic System to Prepare Poly(Lactic-co-Glycolic Acid) Nanoparticles With Encapsulated Protein.

Pharmaceutical research·2024
Same author

Evaluation of PLGA, lipid-PLGA hybrid nanoparticles, and cationic pH-sensitive liposomes as tuberculosis vaccine delivery systems in a Mycobacterium tuberculosis challenge mouse model - A comparison.

International journal of pharmaceutics·2024
Same author

Lesional Psoriasis is Associated With Alterations in the Stratum Corneum Ceramide Profile and Concomitant Decreases in Barrier Function.

Experimental dermatology·2024
Same author

The phase behavior of skin-barrier lipids: A combined approach of experiments and simulations.

Biophysical journal·2024

Area of Science:

  • Dermatology
  • Materials Science
  • Biophysics

Background:

  • Stratum corneum lipids are crucial for skin barrier function.
  • An in vitro model, the stratum corneum substitute (SCS), using synthetic lipids, exists for permeation studies.
  • Improving SCS preparation efficiency and reproducibility is needed.

Purpose of the Study:

  • To develop and evaluate new preparation methods for the stratum corneum substitute (SCS).
  • To assess the properties and performance of SCS prepared by different methods.

Main Methods:

  • Development of two new SCS preparation methods: rotor airbrush and linomat methods.
  • Comparison with a manual airbrush method.
  • Investigation of SCS lipid composition, distribution, and organization.

More Related Videos

A Simplified and Efficient Method to Isolate Primary Human Keratinocytes from Adult Skin Tissue
06:17

A Simplified and Efficient Method to Isolate Primary Human Keratinocytes from Adult Skin Tissue

Published on: August 25, 2018

Establishing a High Throughput Epidermal Spheroid Culture System to Model Keratinocyte Stem Cell Plasticity
10:03

Establishing a High Throughput Epidermal Spheroid Culture System to Model Keratinocyte Stem Cell Plasticity

Published on: January 30, 2021

Related Experiment Videos

Last Updated: Jul 3, 2026

Measuring and Modeling Contractile Drying in Human Stratum Corneum
08:00

Measuring and Modeling Contractile Drying in Human Stratum Corneum

Published on: March 1, 2017

A Simplified and Efficient Method to Isolate Primary Human Keratinocytes from Adult Skin Tissue
06:17

A Simplified and Efficient Method to Isolate Primary Human Keratinocytes from Adult Skin Tissue

Published on: August 25, 2018

Establishing a High Throughput Epidermal Spheroid Culture System to Model Keratinocyte Stem Cell Plasticity
10:03

Establishing a High Throughput Epidermal Spheroid Culture System to Model Keratinocyte Stem Cell Plasticity

Published on: January 30, 2021

  • Evaluation of benzoic acid permeation through SCS.
  • Main Results:

    • SCS prepared by all methods exhibited uniform lipid composition and distribution.
    • Lipids in SCS formed crystalline lamellar phases, mimicking human stratum corneum.
    • Benzoic acid permeation profiles through SCS closely resembled those of human stratum corneum.
    • The rotor method improved efficiency and reproducibility over the manual method.
    • The linomat method minimized lipid loss and yielded more uniform membrane thickness.

    Conclusions:

    • The linomat method is the preferred technique for preparing stratum corneum substitutes.
    • The developed SCS models effectively mimic human stratum corneum for in vitro permeation studies.