Related Experiment Video
Updated: Jul 3, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Real-time three-dimensional TEE-guided repair of a paravalvular leak after mitral valve replacement
Gregory W Fischer1, David H Adams
1Department of Anesthesiology, Mount Sinai School of Medicine, One Gustave L. Levy Place, Box 1010, New York, NY 10029, USA. gregory.fischer@mountsinai.org
Abstract:
Paravalvular leaks are well-known complications seen following cardiac valve surgery. We report a case in which real-time three-dimensional TEE (3D-TEE) was utilized intraoperatively to identify the number, severity, and precise locations of a paravalvular leak at the time of surgery for mitral valve replacement.