Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Hypercapnia test as a predictor of success in spontaneous breathing trials and extubation
Joan M Raurich1, Gemma Rialp, Jordi Ibáñez
1Intensive Care Unit, Hospital Universitario Son Dureta, C/ Andrea Doria 55, 07014 Palma de Mallorca, Spain. jmraurich@hsd.es
Background:
The ventilatory capacity of the respiratory neuromuscular system can be studied with the hypercapnia test.
Objective:
To determine whether decreased response to the hypercapnia test is associated with failure to pass a spontaneous breathing trial (SBT) or extubation failure.
Methods:
We studied 103 intubated patients ready for SBT. We used a hypercapnia test in which we approximately doubled the dead space and thus caused re-inhalation of expired air. We calculated 3 ratios: the ratio of P(0.1) (airway occlusion pressure 0.1 s after the onset of inspiratory effort) during hypercapnia test to baseline P(0.1); the ratio of the change in minute volume [DeltaV(E)] to the change in P(aCO(2)) (we call this ratio the hypercapnic ventilatory response); and the ratio of the change in P(0.1) [DeltaP(0.1)] to the change P(aCO(2)) (we call this ratio the hypercapnic-respiratory-drive response).
Results:
Thirty-six patients failed the SBT, and 11 patients failed extubation. The mean values for the SBT/extubation-success group, the extubation-failure group, and the SBT-failure group, respectively, were: ratio of hypercapnia-test P(0.1) to baseline P(0.1): 4.3 +/- 2.7, 3.7 +/- 1.3, and 3.0 +/- 1.8 (P = .03); hypercapnic ventilatory response: 0.60 +/- 0.35 L/min/mm Hg, 0.50 +/- 0.26 L/min/mm Hg, and 0.31 +/- 0.21 L/min/mm Hg (P < .001); hypercapnic respiratory-drive response: 0.48 +/- 0.24 cm H(2)O/mm Hg, 0.42 +/- 0.19 cm H(2)O/mm Hg, and 0.27 +/- 0.15 cm H(2)O/mm Hg (P < .001). For predicting SBT/extubation success, the sensitivities and specificities, respectively, were: ratio of hypercapnia-test P(0.1) to baseline P(0.1) 0.80 and 0.47; hypercapnic ventilatory response 0.86 and 0.53; hypercapnic respiratory-drive response 0.82 and 0.55.
Conclusions:
The SBT/extubation-failure patients had less response to the hypercapnia test than did the SBT/extubation-success patients, and the hypercapnia test was not useful in predicting SBT or extubation success.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Acute Respiratory Failure-III
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Hyperpnea and Hyperventilation