Related Experiment Video
Updated: Jul 3, 2026

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Retardation of chromate through packed columns of surfactant-modified zeolite
1Faculty of Earth Science, China University of Geosciences, Wuhan 430074, China. li@uwp.edu
Abstract:
In this study, zeolite aggregates with particle size < 0.4, 1.4-2.4, and 3.6-4.8 mm were modified by the cationic surfactant hexadecyltrimethylammonium (HDTMA) bromide to a surfactant loading level of 80, 130, and 250 mmol kg(-1), respectively. The modified and unmodified zeolites were subjected to column tests to study the chromate transport and retardation as affected by particle size. At an input concentration of 11-15 mg L(-1), unmodified zeolite did not retard chromate transport for all three particle size ranges. In contrast, the observed retardation factor for chromate, defined as the number of pore volumes passed when the output concentration equals to half of the input concentration, was 55, 50, and 500 for the columns packed with 3.6-4.8, 1.4-2.4, and < 0.4 mm modified zeolite, respectively. Prolonged tailing of chromate desorption from the modified zeolite was the most striking feature after the feeding solution was switched from chromate to water at full breakthrough. Monitoring of HDTMA and counterion bromide concentration in the effluent revealed that slow but persistent desorption of HDTMA and bromide occurred throughout the transport experiment, which resulted in stripping off of the upper layer of the surfactant bilayer formation on zeolite. The change of HDTMA surfactant surface configuration from bilayer to monolayer resulted in a loss of functionality to absorb and immobilize chromate on the modified zeolite surfaces.
More Related Videos
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography
Ion Exchange
Ion-Exchange Chromatography
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...

