Related Experiment Video
Updated: Jul 3, 2026

Establishment of Deep Hypothermic Circulatory Arrest in Rats
Published on: December 16, 2022
Accuracy of core temperature measurement in deep hypothermic circulatory arrest
Daniele Camboni1, Alois Philipp, Karl-Michael Schebesch
1Department of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany. dcamboni@arcor.de
Abstract:
Deep hypothermia is an effective technique for neuroprotection in cardiac surgery. However, standard body temperature measurement may deviate from actual brain temperature. Therefore, we simultaneously measured brain and core temperatures during neurosurgical interventions in hypothermic circulatory arrest to determine its accuracy. Between 1994 and May 2007, 26 patients (12 female, mean age 46+/-14 years), with complex intracranial aneurysms, underwent resection or clipping applying closed chest cardiopulmonary bypass and hypothermic circulatory arrest via inguinal cannulation. During surgery, temperature probes were positioned in the brain, tympanum, bladder, rectum and pulmonary artery. Mean cardiopulmonary bypass time was 147+/-39 min, mean circulatory arrest time was 28+/-8 min. Brain temperatures were best reflected by bladder and tympanum probes (Pearson's correlation coefficients: bladder=0.83; tympanum=0.80; pulmonary artery=0.63; rectum=0.37; P<0.05). Mean deviations from brain temperature were +0.2+/-2.7 degrees C at the tympanum, -0.8+/-2.6 degrees C in the bladder, -0.7+/-2.6 degrees C in the pulmonary artery and -1.8+/-4.4 degrees C in the rectum. In conclusion, temperature monitoring in the bladder and tympanum reliably reflects brain temperature. Temperature measurements in the pulmonary artery and rectum are less optimal.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

