Related Experiment Video
Updated: Jul 3, 2026

An Automated Differential Nuclear Staining Assay for Accurate Determination of Mitocan Cytotoxicity
Published on: May 12, 2020
A comparison of different cytological stains for biological dosimetry
Thiago Salazar Fernandes1, David Lloyd, Ademir Amaral
1Grupo de Estudos em Radioprotecao e Radioecologia (GERAR), Universidade Federal de Pernambuco, Centro de Tecnologia e Geociencias/Departamento de Energia Nuclear, Cidade Universitaria, Pernambuco, Brazil. thiagosalazar@hotmail.com
Purpose:
This paper examines the relative accuracy of analysis of unstable chromosomal aberrations (dicentrics, rings and fragments) in lymphocyte metaphases using four microscope slide staining options, widely used to assess radiation overdose or to survey occupationally exposed subjects.
Materials And Methods:
Peripheral blood lymphocytes from a healthy donor were irradiated with 1.5 and 3.0 Gy of X-rays at a dose rate of 0.715 Gy/min. Dicentrics were scored by different cytological stains in order to compare block staining: Giemsa and 4', 6-Diamidine-2'-phenylindole dihydrochloride (DAPI); with techniques that highlight centromeres: C-banding and Centromere Multiplex Fluorescence in situ Hybridization (CM-FISH).
Results:
At each of the two doses, the values for dicentrics per cell observed with each staining method were compared. In terms of dose estimation, no statistical difference was observed between the evaluated methods (chi(2) p: 0.27 and 0.64, respectively; analysis of variance - ANOVA, p > 0.99). Therefore, the evidence of centromeres by C-banding and CM-FISH did not promote an increased discovery of dicentrics. On the other hand, when confirmation of unequivocal identification of dicentrics is needed, C-banding and CM-FISH can be a suitable method to confirm its presence. Economical and social factors must be taken into account in the decision of method as well.
Conclusion:
For routine use where several hundreds of cells need to be reliably processed and analyzed daily, processing slides by block staining with Giemsa and DAPI is preferable. However, to assist in resolving the minority of images that are ambiguous, C-banding and CM-FISH provide a better identification of suspected dicentrics.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Karyotyping