Related Experiment Video
Updated: Jul 3, 2026

Affinity Purification of a Fibrinolytic Enzyme from Sipunculus nudus
Published on: June 2, 2023
Plasminogen activator inhibitor-1 removal using dextran sulphate columns. Evidence of PAI-1 homeostasis
Vincent M G Maher1, Yuri Kitano, Clare Neuwirth
1Department of Cardiology, Adelaide Meath Hospital, Dublin, Ireland. vmaher@gmail.com
Patients with high plasma plasminogen activator inhibitor-1 (PAI-1) antigen levels are prone to develop thrombosis. Lowering PAI-1 levels may offer a therapeutic option and help to better understand PAI-1 metabolism. We examined the effect on plasma PAI-1 levels of LDL-apheresis using dextran sulphate (DS) columns in 12 patients (9 male, 3 female, 49 +/- 10 years) with heterozygous familial hypercholesterolaemia and coronary artery disease. One plasma volume equivalent (2.3-4.0 l) was treated during each procedure (at flow rates of 23 +/- 2 ml/min). Lipids and PAI-1 antigen levels were measured in plasma before and immediately after 19 aphereses (once in 7 patients, twice in 3 patients and three times in 2 patients) and also at 3 and 7 days post apheresis in five of these patients and in the column eluates from 8 of these patients. DS-apheresis reduced plasma cholesterol (50 +/- 8%), triglyceride (45 +/- 27%), apolipoprotein B (59 +/- 10%) and PAI-1 antigen levels from 10.2 +/- 5.2 to 6.0 +/- 3.1 ng/ml (P = 0.005). The PAI-I changes were independent of circadian variation. PAI-I bound to the DS-columns (3.51 +/- 1.03 ng/ml filtered plasma) and the percent of filtered PAI-1 that was bound correlated inversely (r = -0.81, P < 0.02) with basal PAI-1 levels indicating a high affinity saturable binding process. In four patients, plasma PAI-1 levels post-apheresis were higher than expected based on the amount of PAI-removed by the DS columns. The difference between the expected and actual PAI-1 level post apheresis, reflecting PAI-1 secretion or extracellular redistribution, correlated inversely with basal PAI-1 levels (r = -0.83, P = 0.01). PAI-1 levels returned to baseline pre-apheresis values 7 days post apheresis. PAI-1 antigen may be removed from plasma without adverse effect, resulting temporarily in its extracellular redistribution and restoration to baseline levels over one week. PAI-1 redistribution particularly when baseline pre-apheresis values were low may reflect a homeostatic mechanism to maintain sufficient PAI-1 levels. Procedures that could selectively remove PAI-1 from plasma may offer a treatment option for those with very high plasma PAI-1 levels and thrombosis.
Patients with high plasma plasminogen activator inhibitor-1 (PAI-1) antigen levels are prone to develop thrombosis. Lowering PAI-1 levels may offer a therapeutic option and help to better understand PAI-1 metabolism. We examined the effect on plasma PAI-1 levels of LDL-apheresis using dextran sulphate (DS) columns in 12 patients (9 male, 3 female, 49 +/- 10 years) with heterozygous familial hypercholesterolaemia and coronary artery disease. One plasma volume equivalent (2.3-4.0 l) was treated during each procedure (at flow rates of 23 +/- 2 ml/min). Lipids and PAI-1 antigen levels were measured in plasma before and immediately after 19 aphereses (once in 7 patients, twice in 3 patients and three times in 2 patients) and also at 3 and 7 days post apheresis in five of these patients and in the column eluates from 8 of these patients. DS-apheresis reduced plasma cholesterol (50 +/- 8%), triglyceride (45 +/- 27%), apolipoprotein B (59 +/- 10%) and PAI-1 antigen levels from 10.2 +/- 5.2 to 6.0 +/- 3.1 ng/ml (P = 0.005). The PAI-I changes were independent of circadian variation. PAI-I bound to the DS-columns (3.51 +/- 1.03 ng/ml filtered plasma) and the percent of filtered PAI-1 that was bound correlated inversely (r = -0.81, P < 0.02) with basal PAI-1 levels indicating a high affinity saturable binding process. In four patients, plasma PAI-1 levels post-apheresis were higher than expected based on the amount of PAI-removed by the DS columns. The difference between the expected and actual PAI-1 level post apheresis, reflecting PAI-1 secretion or extracellular redistribution, correlated inversely with basal PAI-1 levels (r = -0.83, P = 0.01). PAI-1 levels returned to baseline pre-apheresis values 7 days post apheresis. PAI-1 antigen may be removed from plasma without adverse effect, resulting temporarily in its extracellular redistribution and restoration to baseline levels over one week. PAI-1 redistribution particularly when baseline pre-apheresis values were low may reflect a homeostatic mechanism to maintain sufficient PAI-1 levels. Procedures that could selectively remove PAI-1 from plasma may offer a treatment option for those with very high plasma PAI-1 levels and thrombosis.
More Related Videos
10:59Conditional Knockdown of Gene Expression in Cancer Cell Lines to Study the Recruitment of Monocytes/Macrophages to the Tumor Microenvironment
Published on: November 23, 2017
10:31A Liposome Membrane Permeability Assay for Investigating the Effects of Phosphatidylinositol Phosphate Groups on Membranotropic Action of Venom PLA2
Published on: September 26, 2025
Related Concept Videos
Clot Retraction and Fibrinolysis
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Venous Thrombosis III: Interprofessional Care
Peripheral Artery Disease I: Introduction